CeaseFire PFP Ceasefire provides passive fire installation, inspection, rectification, certification and documentation across NSW and the ACT.

Ceasefire PFP is a leading passive fire protection in Australia servicing NSW and the ACT providing a range of passive fire services. Our projects have included both new construction builds, restorations, and repairs. We work closely with a range of manufacturers and suppliers to install only passive fire systems that are tested and approved to the standards required by the National Construction C

ode (NCC) otherwise known as the Building Code of Australia (BCA). All of our passive fire work is installed and certified to comply with the relevant Australian Standards listed in AS1530.4 and AS4072.1. We offer an end-to-end client experience that includes seamless communication, on-site organization, certification and quality work every time. Ceasefire PFP are leading fire protection system suppliers offering services including vermiculite spray, penetration seals, intumescent paint and more. WHAT WE DO
Our passive fire protection services include:

Fire seals and penetration seals. Intumescent paint to structural steel. Vermiculite spray to structural steel and duct. Fyrespray & Fyrewrap for duct fire protection. Textured ceilings (“popcorn ceilings”)
Fire and smoke barriers. FRL upgrades to floors and walls.

Passive Fire Defect of the Week: Missing or Incorrect Fire CollarsFire collars are not one-size-fits-all.The collar need...
01/09/2026

Passive Fire Defect of the Week: Missing or Incorrect Fire Collars

Fire collars are not one-size-fits-all.

The collar needs to suit the pipe material, pipe size, substrate, FRL, orientation and tested installation detail. A collar that is missing, undersized, incorrectly fixed or installed on the wrong substrate may not provide the required fire performance.

Ceasefire PFP inspects, rectifies and certifies passive fire systems across NSW and the ACT.

A useful passive fire defect report should do more than say “non-compliant”.A good report should clearly identify the lo...
26/08/2026

A useful passive fire defect report should do more than say “non-compliant”.

A good report should clearly identify the location, service type, wall or floor construction, FRL requirement, defect description, photos, recommended rectification and close-out status.

Clear reporting makes it easier for builders, facility managers and building owners to understand the risk, plan the rectification works and maintain a reliable compliance record.

Ceasefire PFP provides practical passive fire inspections, defect reporting and rectification support.

Why annular gaps matter in fire-stopping.The gap around a service pe*******on can determine whether a fire-stopping syst...
18/08/2026

Why annular gaps matter in fire-stopping.

The gap around a service pe*******on can determine whether a fire-stopping system is compliant.

If the opening is too large, too small or outside the tested limits, the system may not perform as intended. This is why the substrate, service type, opening size, annular gap, FRL and installation detail all need to be checked before a product is selected.

Passive fire compliance is not guesswork. It needs to be matched to tested evidence.

Passive Fire Defect of the Week: Incorrectly Treated PVC Pipe PenetrationsPVC pipe pe*******ons are one of the most comm...
03/08/2026

Passive Fire Defect of the Week: Incorrectly Treated PVC Pipe Penetrations

PVC pipe pe*******ons are one of the most common areas where passive fire defects occur.

The correct treatment depends on the pipe size, wall or floor type, FRL requirement, opening size and tested system. In many cases, simply sealing around the pipe is not enough.

Ceasefire PFP helps builders and building owners identify the correct tested system, rectify non-compliant installations and provide supporting documentation.

Fire-rated product does not always mean compliant system.Using a fire-rated sealant, collar, wrap or board does not auto...
27/07/2026

Fire-rated product does not always mean compliant system.

Using a fire-rated sealant, collar, wrap or board does not automatically mean the installation is compliant.

Passive fire systems need to match tested system details, including the wall or floor type, service type, opening size, annular gap, FRL, backing material, sealant depth and fixing method.

This is why correct system selection, inspection, documentation and certification matter.

Vermiculite fire spray for structural fire protection.Vermiculite fire spray is commonly used to upgrade the fire resist...
21/07/2026

Vermiculite fire spray for structural fire protection.

Vermiculite fire spray is commonly used to upgrade the fire resistance of structural steel and concrete elements. It provides a practical solution where structural members require an FRL upgrade, particularly in car parks, plant rooms, basements, commercial buildings and infrastructure environments.

Ceasefire PFP installs vermiculite fire spray systems across NSW and the ACT, with project documentation and certification provided on completion.

Passive fire protection is not a “set and forget” item.Over time, new services are installed, access panels are modified...
14/07/2026

Passive fire protection is not a “set and forget” item.

Over time, new services are installed, access panels are modified, walls are damaged and existing fire-stopping systems can be compromised. AS1851 inspect and test routines help identify passive fire defects before they become major compliance issues for building owners, facility managers and strata managers.

Ceasefire PFP provides passive fire inspections, defect reporting, rectification and supporting documentation for buildings across NSW and the ACT.

Passive Fire Defect of the Week: Unsealed Service PenetrationsOne of the most common defects found during passive fire i...
08/07/2026

Passive Fire Defect of the Week: Unsealed Service Penetrations

One of the most common defects found during passive fire inspections is services passing through fire-rated walls or floors without a compliant fire-stopping system.

A fire-rated wall or floor is only effective if every opening through it is treated correctly. The correct system depends on the service type, substrate, annular gap, FRL and tested installation details.

Ceasefire PFP carries out passive fire inspections, rectification works and certification across NSW and the ACT.

Because a fire rating is only as strong as its weakest pe*******on.

Refurbishments introduce hidden risks.Opening up walls or adding new services can compromise existing fire protection sy...
30/04/2026

Refurbishments introduce hidden risks.

Opening up walls or adding new services can compromise existing fire protection systems, often without being immediately visible.

Ceasefire assesses and reinstates passive fire protection in refurbishment projects to maintain compliance.

Because changes to a building shouldn’t reduce its safety.

Learn more, https://ceasefire.com.au/