Fire Fighting System / Sistem Pencegahan Kebakaran

Fire Fighting System / Sistem Pencegahan Kebakaran MOS FIRE PROTECTION AND SYSTEM (MFPS) is registered in Malaysia in March 1997 and been rebranding ba

30/10/2019

Proven experience as maintenance technician

Basic understanding of electrical, hydraulic and other systems

Knowledge of general maintenance processes and methods

Working knowledge of tools, common appliances and devices

Manual dexterity and problem-solving skills

Good physical condition and strength with a willingness to work overtime

High school diploma or equivalent; Certificate in HVAC, building maintenance technology or relevant field will be a plus

22/01/2019

Pernahkah anda menyiapkan langkah pencegahan jika terjadi kejadian sebegini?

Pemadam Api / Fire Extinguisher :
1kg Abc dry powder
2kg Abc dry powder
4kg Abc dry powder
9kg Abc dry powder

2kg co2 gas
5kg co2 gas

Harga termasuk bomba cert. + delivery (klang valley)

Wasap saya utk urusan lanjut
0172096575 (firdaus)
http://www.wasap.my/+60172096575

Alat pemadam api adalah salah satu media pemadaman untuk melawan kebakaran. Dalam menjalankan kerja pemadaman kebakaran,...
29/10/2018

Alat pemadam api adalah salah satu media pemadaman untuk melawan kebakaran. Dalam menjalankan kerja pemadaman kebakaran, alat pemadam api berperanan sebagai “alat bantu mula” iaitu digunakan untuk memadam kebakaran diperingkat awal.

Dalam JABATAN BOMBA DAN PENYELAMAT MALAYSIA atau JPAM, alat ini amat mustahak diketahui dan dipelajari oleh setiap anggota bomba / JPAM / pekerja bagi tujuan memberi tunjuk ajar yang lebih berkesan kepada orang awam tentang cara-cara penggunaanya.

Alat ini diletakkan ditempat yang sesuai dan sentiasa didalam keadaan baik, Penggunaannya hendaklah sesuai dengan jenis kebakaran,Keadaan api semasa kecil, Digunakan oleh seseorang yang bersedia sanggup melakukan dan berkebolehan.

Kaedah Penggunaan Pemadam Api Mudah Alih :-

P- PULL (CABUT)
Cabut pin untuk melepaskan tuil.

A- AIM (HALA)
Hala nozel atau hos ke dasar api.

S- SQUEEZE (TEKAN)
Tekan tuil di atas pemegang untuk
bahan pemadam. Untuk menghentikan
bahan dari keluar, lepaskan tuil.

S- SWEEP (SAPU)
Gerakan nozel atau hos kekiri kanan.
Bergerak ke arah api dengan cermat.

FIRE SUPPRESSION SYSTEM---Fire Suppression System consists of gas cylinders, steel piping, discharge nozzles, heat and/o...
29/10/2018

FIRE SUPPRESSION SYSTEM

---

Fire Suppression System consists of gas cylinders, steel piping, discharge nozzles, heat and/or smoke detectors and a control panel, which monitors the space, activates both visual and audio alarms before releasing the gas.
The carbon dioxide is discharged after a time delay upon detection of fire to warn any occupant to evacuate the room.Such system is usually provided for Server rooms, Clean rooms, Electrical transformer rooms, switch rooms and generator rooms and should not be installed for rooms, which are normally occupied.

Hydrant System---Fire hydrant installation consists of pipework connected directly to the water supply mains to provide ...
29/10/2018

Hydrant System

---

Fire hydrant installation consists of pipework connected directly to the water supply mains to provide water to each and every hydrant outlet and is intended to provide water for the fireman to fight a fire.The water is discharge into the fire engine from which it is then pumped and sprayed over a fire.Where the water supply is not reliable or inadequate,hydrant pumps should be provided to pressurise the fire mains.

Hydrant Outlets

Pillar hydrants should comply with M.S.1395 and located at not more than 30 metres away from the breeching inlet for the building.The hydrant should be not less than 6 metres from the building if it is a high rise building so as to allow fireman to operate the hydrant safely,away from the burning building or falling debris.Generally,hydrants are spaced at not more than 90 metres apart along access roads of minimum 6 metres in width and capable of withstanding a load of 26 tons from fire brigade vehicles.

Hydrant outlets are typically of the twin outlet pillar type with an underground sluice valve.Where these are installed within the owner’s boundary,each should be provided with 30 metres of 65mm dia. canvas hose, instantaneous couplings and nozzles, all housed within a steel cabinet beside the hydrant.Hydrants located along public roads need not be provided with hose stations.Underground hydrants are not encouraged due to the difficulty of access.