Helping property managers ensure fire safety and compliance | NFPAยฎ Certified engineer specializing in fire protection maintenance and installations | Managed fire safety for 70+ high-rise residential properties.

๐–๐š๐ฅ๐š๐ง๐  ๐๐‘๐•, ๐ฌ๐š๐ฌ๐š๐›๐จ๐  ๐›๐š ๐š๐ง๐  ๐ฉ๐ข๐ฉ๐ข๐ง๐  ๐ฌ๐ฒ๐ฌ๐ญ๐ž๐ฆ ๐ฆ๐จ? ๐Ÿ˜จKung tama ang design at sizing ng fire pump system, hindi basta tataas nan...
30/09/2026

๐–๐š๐ฅ๐š๐ง๐  ๐๐‘๐•, ๐ฌ๐š๐ฌ๐š๐›๐จ๐  ๐›๐š ๐š๐ง๐  ๐ฉ๐ข๐ฉ๐ข๐ง๐  ๐ฌ๐ฒ๐ฌ๐ญ๐ž๐ฆ ๐ฆ๐จ? ๐Ÿ˜จ

Kung tama ang design at sizing ng fire pump system, hindi basta tataas nang tataas ang pressure nito hanggang sumabog ang piping.โฃ
ใ€€ใ€€โฃ
Ang fire pump ay may churn or shutoff pressure, o pressure produced during a no-flow condition. Ibig sabihin, may limit ang pressure na kayang i-produce ng pump based on its design and operating condition.โฃ
ใ€€ใ€€โฃ
Dahil dito, hindi automatic na kailangan lagyan ng Main Pressure Relief Valve ang bawat fire pump system.โฃ
ใ€€ใ€€โฃ
Ayon sa NFPA 20, ginagamit lang ang Main Pressure Relief Valve sa specific applications, gaya ng certain engine-driven or variable-speed fire pumps kapag posibleng lumampas ang pressure sa rating ng system components.โฃ
ใ€€ใ€€โฃ
Sa fixed-speed electric fire pump, hindi basta nilalagyan ng Main PRV dahil lang mataas ang pressure. Ang importante ay tama ang pump selection at hindi lalampas ang system pressure sa rating ng piping at components.โฃ
ใ€€ใ€€โฃ
Bago maglagay ng Main PRV, alamin muna kung kailangan talaga ito ng fire pump system mo.

29/09/2026

Aling detector dapat ang mag trigger ng elevator recall? (Clue: not all smoke detectors)

28/09/2026

Hindi ka ba nakaabot sa first early access ng aming 15-minute summarized โ€œNFPA 25 Fundamentalsโ€ video?

Dahil marami pa ring nag-request, weโ€™re opening a few more slots!

Comment โ€œITM VIDEOโ€ and weโ€™ll send the early access link directly to your inbox.

25/09/2026

Nahihirapan ka bang aralin ang NFPA 25 dahil sa dami ng kailangang basahin?

Gumawa kami ng 15-minute video para mas simple at mas madaling maintindihan ang fundamentals ng NFPA 25. And itโ€™s completely free.

Comment โ€œITM VIDEOโ€ and weโ€™ll send the early access link through private message.

23/09/2026

Flow Switch: Alarm ba dapat or supervisory? And why?

๐๐š๐ค๐ข๐ญ ๐ฆ๐š๐ฅ๐ข ๐š๐ง๐  ๐ฆ๐š๐ซ๐š๐ฆ๐ข๐ง๐  ๐ฌ๐ฆ๐จ๐ค๐ž ๐๐ž๐ญ๐ž๐œ๐ญ๐จ๐ซ๐ฌ ๐ฌ๐š ๐ฆ๐ ๐š ๐ฐ๐š๐ซ๐ž๐ก๐จ๐ฎ๐ฌ๐ž?May mga warehouse na sobrang taas ng kisame, pero pagtingala mo...
22/09/2026

๐๐š๐ค๐ข๐ญ ๐ฆ๐š๐ฅ๐ข ๐š๐ง๐  ๐ฆ๐š๐ซ๐š๐ฆ๐ข๐ง๐  ๐ฌ๐ฆ๐จ๐ค๐ž ๐๐ž๐ญ๐ž๐œ๐ญ๐จ๐ซ๐ฌ ๐ฌ๐š ๐ฆ๐ ๐š ๐ฐ๐š๐ซ๐ž๐ก๐จ๐ฎ๐ฌ๐ž?

May mga warehouse na sobrang taas ng kisame, pero pagtingala mo, spot type smoke detector pa rin ang gamit.

Pero sa high ceiling, hindi na suitable ang spot type smoke detector.

Ayon sa Philippine Electronics Code, kapag ang ceiling height ay more than 6 meters, beam-type smoke detector na ang dapat gamitin.

Sa high-ceiling spaces, mas practical ang beam detector. Designed ito para sa malalawak na open areas at mas mahabang detection distance kaysa spot type detectors. Mas kaunti rin ang devices na kailangan dahil mas malayo ang spacing. For example, a Bosch beam detector can reach up to 100 meters between the detector and reflector, with up to 15 meters spacing between detectors.

Mas manageable din ang preventive maintenance dahil karaniwan ay nasa gilid ang device. Hindi kailangan mag-set up ng maraming matataas na scaffolding para lang ma-access ang bawat detector sa ceiling.

Kaya sa high-ceiling warehouses at manufacturing plants, hindi spot type ang tamang detector. Beam detector ang dapat gamitin.

Nakakita na ba kayo ng mataas na warehouse na spot type smoke detector pa rin ang gamit? Kumusta ang maintenance? Share your experience below!

18/09/2026

Another busy day on site, getting things done with the team. ๐Ÿ”ฅ

17/09/2026

NASIRA LANG DETECTOR? MAY PROGRAMMING FEE PA?

PWEDE BANG MAGKABIT NG FOOT VALVE SA SUNCTION NG FIRE PUMP?Marami pa ring gumagawa nito, lalo na kapag underground ang w...
15/09/2026

PWEDE BANG MAGKABIT NG FOOT VALVE SA SUNCTION NG FIRE PUMP?

Marami pa ring gumagawa nito, lalo na kapag underground ang water tank at ang gamit ay horizontal split case o end suction pump.

Pero common does not mean compliant, hindi ito ang tamang solution.

Madalas nilalagyan ng foot valve sa suction side para ma-maintain ang priming. Ibig sabihin, laging puno ng tubig ang suction pipe para makahigop agad ang pump kapag kailangan na itong umandar.

Ang foot valve ay pwedeng magdulot ng problema sa fire pump system.

Una, pwede ka pa ring mawalan ng priming. Kahit check valve type ang foot valve, common fault pa rin nito ang may konting backflow. Kapag nangyari ito, pwedeng mawalan ng tubig ang suction side.

Pangalawa, nagdadagdag ito ng friction loss sa suction side. Kapag naapektuhan ang suction pressure at naging negative, pwede itong humantong sa cavitation ng impeller, na nakakasira sa pump.

Kaya imbes na pilitin ang split case o end suction pump na gumana gamit ang foot valve, ang tamang approach ay gamitin ang vertical turbine pump kapag underground ang water source.

Ayon sa NFPA 20, ito ang tamang pump arrangement para sa ganitong setup. Ang paggamit ng ibang pump type para dito ay hindi allowed.

In short, hindi dapat basta nilalagyan ng foot valve ang suction side. Kapag mali ang application nito, naaapektuhan ang performance at reliability ng fire pump.

Nakakita na ba kayo ng split case o end suction pump na nilagyan ng foot valve? Share mo naman ang experience mo sa comment section.

10/09/2026

Safety first! Kaya dapat laging magsuot ng tamang PPE bago pumasok at magtrabaho sa site. ๐Ÿ‘ท

Address

50 Holy Spirit Drive, Don Antonio Heights
Quezon City
1127

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm
Saturday 8am - 12pm

Telephone

+639567641655

Website

Alerts

Be the first to know and let us send you an email when Flameguard Fire Protection Philippines posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Organization

Send a message to Flameguard Fire Protection Philippines:

Shortcuts

Share