Southern Cathodic Protection Company

Southern Cathodic Protection Company Professional corrosion system design, integrity management, and cathodic protection services.

In 1979, Southern Cathodic Protection Company was founded as a consulting engineering firm to provide professional corrosion engineering services. Our headquarters is in Atlanta, Georgia, with a satellite office in Apopka, Florida. Our clientele includes oil and gas companies, utilities, government agencies, pipeline companies, storage facilities, airports, convenience stores and gas stations. We

have established a reputation in the corrosion control/cathodic protection industry as honest, qualified, reliable professionals. Southern Cathodic Protection Company is dedicated to providing viable, cost efficient and effective corrosion control applications to its clients backed by quality engineering and customer service.

10/22/2021

SCPC is excited to have the opportunity to exhibit at the American Public Gas Association Operations Conference! The event starts on Tuesday, October 26th and ends the 28th. Stop by our booth and chat for a bit, we are excited to see everybody and look forward to the event!

08/06/2017

Dallas Cooper has joined Southern Cathodic Protection Company team in Atlanta, GA. Miss Cooper has been appointed as Southern Cathodic Protection Company's Marketing and Compliance Assistant.

Dallas Cooper has joined Southern Cathodic Protection Company team in Atlanta, GA. Miss Cooper has been appointed as Southern Cathodic Protection...

08/05/2017

Alex Hackworth has joined the Southern Cathodic Protection Company team in Atlanta, GA. Miss Hackworth has been appointed as Southern Cathodic Protection Company 's Corrosion Consultant.

Alex Hackworth has joined the Southern Cathodic Protection Company team in Atlanta, GA. Miss Hackworth has been appointed as Southern Cathodic Protect...

08/04/2017

Austin Ray joined the Southern Cathodic Protection Company team in May of 2016 in Atlanta, GA office. Mr. Ray was promoted from the Marketing and Compliance Manager to the Business Development Manager in November 2016.

Austin Ray joined the Southern Cathodic Protection Company team in May of 2016 in Atlanta, GA office. Mr. Ray was promoted from the Marketi...

Check out our most recent newsletter!
08/04/2017

Check out our most recent newsletter!

Transit systems experience corrosion problems relating to the discharge of stray current that can adversely affect underground utilities. 

Cathodic protection for underground storage tankFor UST Owners Allow Southern Cathodic Protection Company to assist you ...
03/31/2016

Cathodic protection for underground storage tank

For UST Owners Allow Southern Cathodic Protection Company to assist you in protecting your investment by preventing leaks and meeting state and federal regulations for underground storage tanks and piping.

Even without the strigent EPA regulations mandating corrosion control on underground storage tanks, a sound leak control program makes economic sense. Southern Cathodic Protection Company provides professional engineering services to assist tank owners in preventing leaks and achieving regulatory compliance.

These services include:

Corrosion Surveys to collect site specific information concerning soil characteristics, resistivity, electrical continuity, stray currents and interference.
Statistical Corrosion Probability (SCP) analysis for evaluating underground storage tank suitability for upgrading with cathodic protection in accordance with ASTM standards.
Testing and Design of tanks and piping, provided by registered Professional Engineers and NACE International Certified Corrosion Specialists, insures optimum corrosion control and operating efficiency.
Cathodic Protection Installations extend the life of both tanks and piping indefinitely. The cathodic protection cost represents a mere fraction of tank replacement costs. Cathodic protection can be applied to old or new tanks without disrupting operations.
Remote Monitoring uses computers and modems to automatically acquire and verify cathodic protection operating data while maintaining required records.
Statistical Inventory Control utilizes daily stick readings to economically meet EPA tank tightness and monthly monitoring requirements.
Environmental Assessment is performed for buyers and sellers to protect against financial liability resulting from contaminated soils.-

03/14/2016

Shows a blog entry in detail

03/14/2016

Utilities are gearing up to celebrate Natural Gas Utility Workers’ Day - March 18th! Much appreciation to APGA and their Marketing and Sales Committee for several months of planning to claim the special day for the hard working employees of the industry! More Info in the SGA Blog - https://www.southerngas.org/communications-center/sga-blog/

02/22/2016

PIPELINE ENGINEERING

Cathodic Protection for Pipelines

Southern Cathodic Protection Company (SCPC) has demonstrated experience in virtually all aspects of the pipeline transmission and distribution industry from routine operation and maintenance-related matters to engineering design and construction. The firm has successfully completed a wide variety of projects ranging from relatively small scopes of work through major construction projects. As a result of our 200+ years combined experience in gas and liquid pipeline engineering, SCPC understands the importance of close communication with the client throughout any project we undertake. Our employees are well versed in the regulatory codes affecting the natural gas and liquid pipeline industry, i.e., Title 49 CFR Parts 191, 192, 195 and 199.

SCPC provides a wide range of engineering services to the pipeline industry including many areas of consulting expertise and project management. The following will outline the variety of services available to natural gas and liquid pipeline operators:

Pipeline Engineering

Piping System Computer Modeling - utilizing various software packages
GIS/ERSI Mapping & Software
Operations and Maintenance Plans - updates and audits
Operator Qualification Plans - updates and audits
New Business System Design
Renewal System Design
Pipeline System Pressure Improvement Design
Pipeline System Pressure Up-rating Procedures - production and implementation
Engineering/Safety Audits for OPS/PHMSA regulatory compliance
Pipeline System Over-Pressure Protection Design
Commercial/Industrial Meter Set Design
Pipeline Class Location Studies
Integrity Management Plans (IMP) -Production and Implementation
IMP High Consequence Area (HCA) Evaluations
External Corrosion Direct Assessment (ECDA) Survey Project Management

Feasibility Studies

Schedule Control

Project Organization & Staffing

Alignment & Progress Meetings

Project Status Reports

Scope Change Management

01/07/2016

Facts About Impressed Current Cathodic Protection (ICCP)

The cathodic protection current of an Impressed Current Cathodic Protection (ICCP) system is obtained from an external source such as the local utility company which can impose a current sufficient to counteract the existing currents of the corrosion cell. The current is "impressed" on the corroding structure through the use of relatively inert anode materials.

Typical Components

Typically an impressed current cathodic protection system for a concrete structure will contain the following components.

DC Power source
Inert anode material
Wiring and conduit
Monitoring devices
The local utility is the most common source of external power for the system. This is of course AC current and must therefore be converted to DC current for use in the CP system. Rectifiers are available in a variety of sizes and types to satisfy the needs of all corrosion prevention situations.

The Anode

Anode material in an ICCP system is a relatively inert material such as catalyzed titanium. By using relatively inert materials, anode consumption is minimized.

The anode is one of the most critical components of the system because it distributes protective current to the reinforcing steel. It is also the location of all anodic reactions in the system and will therefore eventually be consumed. It is desirable to use anode material with a long life expectancy which can be accurately predicted. Catalyzed titanium is such a material.

Selection of catalyzed titanium as the anode material will yield a life expectancy of more than 40 years for existing structures and more than 100 years for new structures.

Maintenance

After installation minimal maintenance is required to insure proper functioning of an ICCP system. This involves visual inspection and periodic monitoring of the voltage and current as well as insuring proper supply of DC current to the anode. During installation of the system it is common practice to imbed silver/silver chloride reference electrodes to facilitate routine monitoring.

Published in Corrosion Education

Address

780 Johnson Ferry Road NE Suite #225
Atlanta, GA
30342

Alerts

Be the first to know and let us send you an email when Southern Cathodic Protection Company posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Organization

Send a message to Southern Cathodic Protection Company:

Share