Flameoffcoatings, Inc.

Flameoffcoatings, Inc. FlameOFF® Coatings, Inc. is a leading developer of fire resistant technologies that protect lives a

FlameOFF® Coatings, Inc manufactures fire resistant intumescent paints and fire retardant coatings that are IBC/NFPA Code Compliant for ASTM E-119 fire endurance ratings that require 1 or 2 hour fire protection. FlameOFF® Coatings, Inc also offers lesser fire ratings such as thermal barrier (UL 1715) and flame-spread (ASTM E-84). Our intumescent coatings provide solutions to fire protection design requirements for new construction and existing construction projects.

Fireproofing gets damaged on active jobs. What matters is what the repair costs. Fire Barrier Paint is built to be patch...
08/11/2026

Fireproofing gets damaged on active jobs. What matters is what the repair costs.

Fire Barrier Paint is built to be patched.

Damaged? Rebuild the required thickness by spray or brush. Once it's dry, smooth and finished, a topcoat can go on. ✅

Two conditions decide if the repair holds:
1️⃣ Same surface prep as the original - clean, dry, contaminant-free
2️⃣ Built back to FULL original thickness. Not close. Full.

Verify it the same way: wet film gauge during application, electronic DFT gauge for final. (AWCI 12-B, IBC 1705.14)

And no reinforcing mesh - nothing embedded to reconstruct.

Scoping a repair? Run required thickness section by section before ordering material.

Steel Coverage Calculator https://flameoffcoatings.com/steel-coverage-calculator

Fire retardant treatment on wood usually costs you the wood.Exposed timber gets specified because of how it looks - the ...
08/06/2026

Fire retardant treatment on wood usually costs you the wood.

Exposed timber gets specified because of how it looks - the grain, the color, the tonal variation. Anything that obscures that defeats the reason it was chosen.
FR Clear dries clear. It's a fire retardant coating for wooden surfaces and other natural or synthetic materials, with a clear finish that lets materials keep their original color, appearance, and durability. It maintains the original properties of the materials it's applied to.

The performance: Class A flame spread and smoke development rating to ASTM E84 / UL 723, UL Classified on wood. Tested and certified to NFPA 701, 705, and 260.
It's water-based, non-toxic, odorless, and lightweight, and it applies by spraying, dripping, or padding.
One distinction worth being precise about: this is flame spread performance. It is not an hourly fire endurance rating.

Specifying exposed timber on a project right now? Send us the assembly and the code requirement you're working to. We'll confirm whether FR Clear meets it - or tell you plainly that it doesn't and point you to what does.

A hospital doesn't close for renovation.But the steel gets exposed, and the fire rating has to come back - with patients...
07/30/2026

A hospital doesn't close for renovation.

But the steel gets exposed, and the fire rating has to come back - with patients thirty feet away.
Replacing cementitious means containment and downtime. Solvent-based coatings mean odor.
Thin-film intumescent means neither. Water-based, low VOC, no mesh, no bulk - and no topcoat required in interior conditioned spaces.
FlameOFF Fire Barrier Paint. UL Classified, ICC Listed. 1 and 2 hour ratings on interior structural steel.

Phased scope on your desk? Let's talk sequencing before the spec is locked.
https://lnkd.in/g4b54AEs

The  #1 fireproofing repair mistake: patching the symptom, not the cause.Many just cover up cracks, repaint over the sur...
07/23/2026

The #1 fireproofing repair mistake: patching the symptom, not the cause.

Many just cover up cracks, repaint over the surface, or replace a single layer of coating. It looks fine… until the next fire.

Real fireproofing starts with finding the root cause: damaged structure, wrong materials, or improper installation.
Fix the cause - get real protection.
Patch only what’s visible - risk the entire object.
Want reliable fireproofing repair done right the first time?

Contact FlameOFF specialists - we’ll handle it properly.
https://flameoffcoatings.com/contact-us?utm_source=facebook&utm_campaign=07-23-2026-Intumescent-Paint-Experts

That fine grey dust under your steel? It’s not just housekeeping.Grey powder under steel structures usually comes from c...
07/15/2026

That fine grey dust under your steel? It’s not just housekeeping.

Grey powder under steel structures usually comes from cracking cementitious fireproofing - a common problem in offices, factories, hospitals and clean zones.
Tired of constant cleaning? Try FlameOFF® Fire Barrier Paint - thin-film
intumescent coating with no dust or shedding.

1. 1-2 hour fire rating for steel (UL Classified)
2. Water-based, low-VOC, GREENGUARD Gold
3. Applies easily like regular paint, lightweight

Learn more: https://flameoffcoatings.com/intumescent-fire-resistant-paint?utm_source=facebook&utm_campaign=2026-07-15fine+grey+dust+under+your+steel

Myth: “If a coating has a fire rating, it will pass inspection.” Not quite.A fire rating is proven in the lab. Inspectio...
07/08/2026

Myth: “If a coating has a fire rating, it will pass inspection.” Not quite.

A fire rating is proven in the lab. Inspection is proven on the jobsite. They are two different things.
FlameOFF Fire Barrier Paint is ICC-ES listed and UL classified under ASTM E119 (1–2 hours). But the rating only holds if application is done exactly to spec.

The most common failure is insufficient dry film thickness (DFT). Per ESR-3874, special inspection is required (IBC 1705). If any reading falls below 80% of the specified thickness, that area must be recoated.
Key conditions: Steel must be primed with alkyd or acrylic primer, and application only above 50°F (10°C).

The rating opens the door - proper application and documentation get you through it.

Planning a fire protection project? Contact our technical team before starting - we’ll verify your spec and DFT so you pass inspection the first time.
Contact Technical Support → https://flameoffcoatings.com/contact-us?utm_source=facebook&utm_medium=social&utm_campaign=2026-07-08_Flameoff

Tomorrow is 4th of July!🎆Ready to make tomorrow a real show with fireworks and great mood?Hope the holiday will be brigh...
07/03/2026

Tomorrow is 4th of July!🎆

Ready to make tomorrow a real show with fireworks and great mood?
Hope the holiday will be bright, delicious and full of nice moments.
Early congratulations from Flameoff!

How are you celebrating? Share your plans in the comments✨

07/01/2026

When the steel IS the design, the fireproofing can't hide it.

In modern architecture, steel is often a visible and intentional design element. But traditional fireproofing methods conceal its texture and ruin the clean aesthetic.
FlameOFF delivers reliable fire protection while preserving the modern, exposed look of the steel structure.

Calculate the required coating thickness right now:
🔗 https://lnkd.in/eUeENGew
Or call our technical team: 866-406-1160
FlameOFF - fire protection that respects the design.

Your fireproofing met the rating. It still failed inspection. Why?FlameOFF® Fire Barrier Paint is tested and certified t...
06/25/2026

Your fireproofing met the rating. It still failed inspection. Why?
FlameOFF® Fire Barrier Paint is tested and certified to ASTM E119/UL 263 for 1- and 2-hour ratings.

But even the best product fails inspection if:
1. The required Dry Film Thickness (DFT) isn’t achieved
2. Surface preparation is poor
3. Application guidelines aren’t followed exactly

Proper thickness + correct application = passing inspection.
Need help? Our team is here:
866-406-1160

Before / After: FlameOFF Fire Protection in ActionBefore:Unprotected steel structures at risk. In case of fire, the meta...
06/17/2026

Before / After: FlameOFF Fire Protection in Action

Before:
Unprotected steel structures at risk. In case of fire, the metal would rapidly lose strength and collapse within minutes.

After:
FlameOFF Fire Barrier Paint applied.
The steel is now reliably protected with up to 90-120 minutes of fire resistance.

Key results:
1. Meets required fire safety standards
2. Maintains clean architectural appearance
3. Lower long-term maintenance costs
4. Easy local repairs

FlameOFF doesn’t just protect - it gives steel structures critical time during a fire, helping save lives and property.

Real protection. Visible difference.
Want to protect your project with reliable fire protection?
📩 Write comment for consultation and calculation below.

Address

3915 Beryl Road Suite 130
Raleigh, NC
27607

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 5pm

Telephone

+18664061160

Alerts

Be the first to know and let us send you an email when Flameoffcoatings, Inc. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Organization

Send a message to Flameoffcoatings, Inc.:

Shortcuts

Share